Apex Digital apex 10 Manual de Serviço Página 104

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 103
106 APEX — Installation and Service Manual
Section 3 — Installation
VDE EMI/RFI Modifications to Matrix Cables – user-supplied matrix cables for VDE
installations require a ferrite core over each end of the cable, adjacent to the
connector as described in
Figure 49.
Figure 49. Matrix Cable VDE Modifications
Type 43 material
0.375 inch (9.53 mm) or larger inside diameter
0.95 inch (24.13 mm) length (or longer)
Type 43 material sources
Fair-Rite, part no. 2643625102
Fair-Rite Products Corp., P.O.Box J, Commercial Row,
Wallkill, NY 12589, USA; Tel. (914) 895-2055.
Chomerics, part no. 83-10-A637-1000
Chomerics Inc., 77 Dragon Ct., Woburn, MA 01888
USA; Tel. (617) 935-4850.