APEX — Installation and Service Manual 101
Frame Settings
Frame Settings
Note On all the rotary switches, use the triangular arrowhead for pointing to the
desired setting (not the screwdriver slot).
SW1 Switch (Apex Plus Systems Only)
Switch SW1 (Figure 44) applies only to Apex Plus systems. Positions for
setting switch settings for system size and number of chassis with SW1 are
given in
Table 3
Figure 44. SW1 Switch
Table 3. SW1 Switch Settings (Apex Plus Only)
System Size Number of Chassis
SW_1 Position
(setting applies to all
chassis in system)
512 X 512 2 (1 In + 1 Out) 0
512 X 1024 (1) Rx to (2) Tx 1
512 X 1536 (1) Rx to (3) Tx 2
512 X 2048 (1) Rx to (4) Tx 3
1024 X 0512 (2) Rx to (1) Tx 4
1024 X 1024 (2) Rx to (2) Tx 5
1024 X 1536 (2) Rx to (3) Tx 6
1024 X 2048 (2) Rx to (4) Tx 7
1536 X 0512 (3) Rx to (1) Tx 8
1536 X 1024 (3) Rx to (2) Tx 9
1536 X 1536 (3) Rx to (3) Tx 10
1536 X 2048 (3) Rx to (4) Tx 11
2048 X 0512 (4) Rx to (1) Tx 12
2048 X 1024 (4) Rx to (2) Tx 13
2048 X 1536 (4) Rx to (3) Tx 14
2048 X 2048 (4) Rx to (4) Tx 15
2
3
4
5
67
8
9
10
11
12
13
14 15 1
0
SW1